Home » Simplify your calculations with ease. » Environmental » EUI (Energy Use Intensity) Calculator

EUI (Energy Use Intensity) Calculator

Show Your Love:

The EUI (Energy Use Intensity) Calculator measures the energy efficiency of a building by calculating the amount of energy it consumes per unit of floor area over the course of a year. EUI is a widely used metric in the fields of energy management, green building certification, and real estate performance benchmarking.

By analyzing EUI, building owners, facility managers, engineers, and sustainability professionals can identify inefficient buildings, compare performance across properties, set energy reduction goals, and track improvements over time. It also supports compliance with programs like ENERGY STAR, LEED, and government-mandated energy disclosure laws.

See also  Biotic Index Calculator

Formula of EUI (Energy Use Intensity) Calculator

EUI = Total Annual Energy Consumption / Gross Floor Area

Where:

  • EUI is expressed in either kBtu per square foot per year (kBtu/ft²/year) or kWh per square meter per year (kWh/m²/year)
  • Total Annual Energy Consumption is the sum of all energy types (electricity, gas, oil, etc.) used by the building in a year, converted to a single unit (kBtu or kWh)
  • Gross Floor Area is the total enclosed floor area of the building, including all spaces served by energy systems

Conversion:

1 kWh = 3.412 kBtu

Use this conversion to maintain unit consistency if your energy data includes mixed units.

Helpful Reference Table

Below is a reference table to help estimate EUI values for various types of buildings using standard benchmarks.

See also  XDC Calculator Online
Building TypeTypical EUI (kBtu/ft²/year)Equivalent (kWh/m²/year)
Office (Standard)77243
Hospital234736
School (K-12)50158
Retail Store93293
Apartment (Multifamily)58183

These values provide a starting point to compare your calculated EUI against common industry averages and determine whether a building is above or below expected efficiency.

Example of EUI (Energy Use Intensity) Calculator

Let’s calculate the EUI for an office building that uses 950,000 kWh of electricity annually and has a gross floor area of 45,000 ft².

Step 1: Convert energy to kBtu
Total Energy = 950,000 × 3.412 = 3,241,400 kBtu

Step 2: Apply the formula
EUI = 3,241,400 / 45,000 ≈ 72.03 kBtu/ft²/year

See also  National Tree Benefit Calculator Online

Result: The building’s Energy Use Intensity is approximately 72.03 kBtu/ft²/year, which is slightly below the typical EUI for office buildings, indicating relatively good performance.

Most Common FAQs

Why is EUI important?

EUI helps evaluate how efficiently a building uses energy relative to its size. It supports energy audits, helps identify savings opportunities, and is critical for sustainability reporting and benchmarking.

What is a good EUI?

A "good" EUI depends on building type, climate, and usage patterns. Generally, the lower the EUI, the better the energy performance. However, high-intensity buildings like hospitals naturally have higher EUI values.

Does EUI include all energy types?

Yes. EUI calculations should include all energy consumed by the building, such as electricity, natural gas, fuel oil, and district heating or cooling. Each source should be converted to a consistent energy unit.

Leave a Comment