Conformity Index Calculator

Show Your Love:

A Conformity Index Calculator is a tool used in radiotherapy to evaluate how well the prescribed radiation dose conforms to the planned target volume (PTV). This metric is crucial for ensuring that the radiation treatment is precise, delivering the optimal dose to the tumor while minimizing exposure to surrounding healthy tissues. It is widely used by medical physicists and oncologists during treatment planning.

Formula of Conformity Index Calculator

Step 1: Understand the Formula
The Conformity Index (CI) is calculated as:
CI = Volume of PTV covered by the prescription dose (V_PTV) / Total volume receiving the prescription dose (V_Total)

Where:

  • V_PTV is the volume of the Planned Target Volume (PTV) that is covered by the prescription dose.
  • V_Total is the total volume of tissue receiving the prescribed dose, including regions outside the PTV.

Step 2: Calculate Each Component

  • V_PTV is determine using imaging or treatment planning software to identify the overlap between the PTV and the prescribed dose region.
  • V_Total is calculate as the sum of all tissue volumes receiving the prescribed dose.

Step 3: Calculate the CI
Substitute the calculated values of V_PTV and V_Total into the formula to determine CI.

Step 4: Interpretation

  • CI close to 1: Indicates excellent conformity, where the radiation dose closely matches the PTV.
  • CI greater than 1: Suggests excessive dose spill outside the PTV.
  • CI less than 1: Indicates underdosing within the PTV.

Step 5: Adjust for Alternative Formulas
In some scenarios, variations like the Paddick Conformity Index are use. This formula is:
Paddick CI = (V_PTV)^2 / (PTV × V_Total)
Here, PTV represents the total volume of the Planned Target Volume.

General Reference Table for Conformity Index Interpretations

CI ValueInterpretationAction Needed
0.95-1.05Optimal conformityNo changes required
>1.05Overdose outside the PTVAdjust beam or shielding
<0.95Underdose within the PTVRe-evaluate dose planning

Example of Conformity Index Calculator

Suppose a treatment plan delivers radiation to a tumor with the following data:

  • V_PTV = 150 cm³ (volume of PTV covered by the prescription dose)
  • V_Total = 200 cm³ (total volume receiving the prescribed dose)

To calculate CI:
CI = V_PTV / V_Total
CI = 150 / 200 = 0.75

Interpretation: The CI is less than 1, indicating that the PTV is underdose. The treatment plan needs to be adjust to improve conformity.

Most Common FAQs

1. What is the ideal Conformity Index?

An ideal CI is close to 1, signifying that the prescribed radiation dose aligns well with the PTV.

2. How is the Conformity Index use in radiotherapy?

It ensures treatment precision by identifying overdoses or underdoses and helps optimize the radiation plan for better patient outcomes.

3. What is the difference between Conformity Index and Paddick Conformity Index?

The standard CI evaluates the ratio of V_PTV to V_Total, while the Paddick CI incorporates the total PTV volume into the calculation, offering a more refined measure of dose distribution.